Sprinkler Flex×テクノフレックス - メーカー・企業と製品の一覧

Sprinkler Flexの製品一覧

1~2 件を表示 / 全 2 件

表示件数

Firefighting equipment hose reel connector Sprinkler flex SP-2

Since its release, it has achieved sales of over 2 million units.

Cost reduction in building equipment is essential, and fire protection piping systems are no exception. The SP-2 type has evolved from traditional flexible hoses, born with the concept of "keeping performance while being simpler." ◆◇◆Features◆◇◆ ◆All Stainless Steel The connecting fittings are made of SUS304 steel. The flexible part of the main body is made of SUS316 steel, and the connecting fittings at both ends are made of SUS304 steel. It is ideal for dry and pre-action piping. ◆High Corrosion Resistance It is assembled using TIG welding, which is most suitable for stainless steel connections. Additionally, the entire product undergoes heat treatment, ensuring reliable corrosion resistance. ◆Simple To achieve weight reduction, the outer braid has been removed. Furthermore, there is only one connection point for piping, allowing for reduced installation inspection time. ◆Inspection Product Based on the Specifications of the Japan Water Works Association (JWWA) Compatible with fire protection systems branching from water supply piping. An inspection product means that it has been tested by a third-party inspection organization, the Japan Water Works Association, based on the specifications of the relevant business operator, and is provided to customers as compliant. ◆◇◆For more details, please request materials or download the catalog◆◇◆

  • Piping Equipment
  • Water and sewerage pipe fittings
  • Rock drills, demolition machines, and excavators

ブックマークに追加いたしました

ブックマーク一覧

ブックマークを削除いたしました

ブックマーク一覧

これ以上ブックマークできません

会員登録すると、ブックマークできる件数が増えて、ラベルをつけて整理することもできます

無料会員登録

Firefighting equipment hose reel fitting Sprinkler Flex SP-SF

Passed the easy heat resistance test! Achieved high workability with the rotating nipple structure!

The "Sprinkler Flex / SP-SF" from Techno Flex Co., Ltd. significantly improves the installation performance of piping connections due to its rotating nipple structure. It meets the light heat resistance test standards of Fire Department Notification No. 31, allowing it to be installed in various locations. Additionally, it not only prevents melting or deformation due to fire but also maintains the shut-off performance of the rotating nipple section even during temperature increases caused by fire. We have newly adopted the "Silent Bellows," which is less prone to resonance (bellows fatigue) during the operation and water discharge of the sprinkler head. We are here to assist you in building a safer sprinkler system. 【Features】 ■ Rotating nipple structure ■ Passed light heat resistance test ■ Adoption of Silent Bellows *For more details, please refer to the catalog or feel free to contact us.

  • Fittings

ブックマークに追加いたしました

ブックマーク一覧

ブックマークを削除いたしました

ブックマーク一覧

これ以上ブックマークできません

会員登録すると、ブックマークできる件数が増えて、ラベルをつけて整理することもできます

無料会員登録